Schneider Electric A9V31425

A9V31425 Acti9 Vigi iC60 Earth Leakage Add-On Block, 4P 25A

MPN A9V31425
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V31425, 4P, 25 A, 30 mA, Type A-SI, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V31425 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width54 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9V31425 is an Acti9 Vigi iC60 add-on residual current device — a 4-pole block rated 25 A with 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised). It clips onto the DIN rail alongside the matching iC60 MCB and connects via screw terminals. The 30 mA trip threshold covers standard personnel protection in AC networks, while the Type A-SI designation means it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads.

The 25 A rated current matches the iC60 MCB it pairs with — sized for a 25 A outgoing circuit. Type A-SI (Super Immunised) is the key differentiator: it is designed to stay latched through 8/20 µs impulse surges up to 3000 A without tripping, which matters on circuits with switching power supplies, VFDs, or LED drivers that generate high-frequency leakage. The voltage-independent tripping technology means the RCD operates without needing a separate power supply — it uses the fault energy itself to trip, so it works even if the neutral is lost upstream.

Mounts via clip-on to standard DIN rail, occupying 6 modules of 9 mm pitch (54 mm total width). The trip indicator gives a local visual signal after a fault event, which speeds troubleshooting on a live panel.