Skip to main content
Schneider Electric A9V39463

Schneider Electric A9V39463 Acti9 Vigi iC60, 4P, 63A, A-SI,

MPN A9V39463
Active

Schneider Electric Acti9 Vigi iC60 add-on RCD, 4P, 63 A, Type A-SI, 1000 mA, selective, 230…415 VAC, clip-on DIN rail, IP20/IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V39463 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width135 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9V39463 is an Acti9 Vigi iC60 add-on residual current device, 4 poles, rated 63 A, with a 1000 mA earth-leakage sensitivity.

The 1000 mA sensitivity and Type A-SI (Super Immunised) characteristic mean this RCD is designed for circuits where nuisance tripping from high-frequency harmonics or pulsed DC must be avoided — typical for variable-speed drives, UPS outputs, or industrial equipment with electronic loads. The 'selective' time delay (S-type) coordinates with downstream RCDs: it holds during a fault long enough for the downstream device to clear first, so only the faulted branch drops out. Rated operational voltage is 230…415 V AC, 50/60 Hz, covering single-phase and three-phase networks up to 415 V line-to-line. The 4-pole construction handles three-phase plus neutral, so it fits three-phase outgoing feeders in distribution boards. The voltage-independent tripping mechanism means the RCD detects leakage current and trips even if the phase voltage is lost — a safety advantage over electronically dependent types that may fail to trip on a lost neutral.

Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (135 mm). Tightening torque 3.5 N.m. The add-on design screws directly to the outgoing side of an iC60 MCB — no extra wiring between the two.

MPN
A9V39463