Skip to main content
Schneider Electric A9V71463

Schneider Electric A9V71463 Acti9 Vigi iC60, 4P, 63A, 30mA,

MPN A9V71463
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V71463, 4P, 63 A, 30 mA, Type A-SI, instantaneous, 230 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V71463 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz conforming to EN/IEC 61009-1 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width63 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9V71463 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a 4-pole, 63 A unit with 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised), instantaneous trip. It clips onto the DIN rail alongside the matching iC60 MCB to provide combined overcurrent and earth-leakage protection in a two-module stack. The voltage-independent trip mechanism means it clears a ground fault even if the line voltage collapses — a real advantage on circuits where a lost neutral could otherwise silence a conventional RCD.

The 30 mA sensitivity catches leakage that would be hazardous to personnel; Type A-SI (Super Immunised) handles pulsed DC fault currents from electronics and resists nuisance tripping from high-frequency noise, so it's a good fit on circuits feeding VFDs, UPS units, or switching power supplies. Instantaneous trip means no intentional time delay — it clears within the standard RCD response window, which is what you want for shock protection but means you cannot coordinate it downstream of another instantaneous RCD. The 8/20 µs impulse withstand of 3000 A per IEC 61009-1 confirms it survives surge events without internal damage.

Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (63 mm). The screw connection to the adjacent MCB means you wire the phase and neutral through the MCB first, then the RCD picks up the outgoing side. Trip indicator on the front gives a local visual of whether it's the RCD that opened, which saves chasing the wrong device in a multi-way board.

MPN
A9V71463