Schneider Electric A9W24263 Acti9 Vigi iC60, 63A 300mA RCBO

MPN A9W24263
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 2P, 63 A, 300 mA, Type A, clip-on DIN rail, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W24263 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width72 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9W24263 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a voltage-independent, Type A earth-leakage module that clips onto the outgoing side of an iC60 MCB to add 300 mA ground-fault protection. Rated 63 A continuous at 230/415 V AC, 50/60 Hz, it covers the standard residential and light-commercial outgoing circuits. The 2-pole form factor (2P) suits single-phase or two-wire protected circuits, and the instantaneous trip means no intentional delay — it clears the fault as fast as the internal sensing allows.

The 63 A rated current (In) and 300 mA earth-leakage sensitivity are the two numbers that decide whether this RCD fits your BOM line. At 63 A it matches the thermal capacity of a 63 A MCB upstream — pair it with a lower-rated breaker and the RCD is over-specced but still fine; pair it with a higher-rated breaker and the RCD becomes the weak link. The 300 mA sensitivity is a standard for general-purpose socket-outlet protection in many IEC territories (IEC 61009-1 governs the combined RCBO function here). Type A detection handles pulsating DC fault currents from electronics and rectifiers — the most common residual-current shape outside pure sinusoidal AC. Mounting is clip-on DIN rail (4 x 9 mm pitches wide, so 36 mm). The tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable, stripped 14 mm, tightened to 3.5 N·m.

MPN