Skip to main content
Schneider Electric A9Y80325

Schneider Electric A9Y80325 Acti9 Vigi iC40 RCD, 3P 25A 30mA

MPN A9Y80325
Obsolete

Schneider Electric Acti9 Vigi iC40 add-on residual current device, A9Y80325, 3P, 25 A rated current, 30 mA sensitivity, Type A, voltage-independent tripping.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y80325 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width90 mm
Height99.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Y80325 is an Acti9 Vigi iC40 add-on residual current device (RCD) — a 3-pole unit rated for 25 A continuous current with 30 mA earth-leakage sensitivity, Type A protection, and voltage-independent tripping. Type A means it catches pulsating DC fault currents from electronics and rectified loads, not just pure AC sine-wave faults.

Rated 25 A at 400 V AC (50/60 Hz) — this RCD is sized for a 25 A outgoing circuit, typically feeding a sub-distribution board, a bank of lighting, or a mixed socket-outlet circuit. Type A detection covers smooth DC residual currents up to 6 mA plus pulsating DC — essential where the downstream load includes single-phase rectifiers, switched-mode power supplies, or variable-speed drives. Voltage-independent tripping means the device stores enough energy from the fault itself to open the contacts; it does not need an external control voltage to operate, so it works even if the neutral is lost upstream. The tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible copper; the tightening torque is 2 N·m on the bottom connections.

Pollution degree 3, rated impulse withstand voltage 4 kV. The insulation voltage is rated 440 V AC. Storage temperature range -40…85 °C; operating ambient -25…60 °C. Maximum operating altitude 2000 m without derating. Relative humidity tolerance 95 % at 55 °C.

MPN
A9Y80325