Schneider Electric A9Y84740

A9Y84740 Acti9 Vigi iC40 40A 30mA RCD, 3P+N

MPN A9Y84740
Active

Schneider Electric Acti9 Vigi iC40, add-on residual current device, 3P+N, 40 A, 30 mA, Type A-SI, 400 V AC, DIN rail clip-on, white.

$386.48 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y84740 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width90 mm
Height99.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

It adds earth-leakage protection to a 3P+N circuit rated at 40 A and 400 V AC, with a 30 mA sensitivity and Type A-SI (Super Immunised) waveform discrimination. The 4-module (9 mm pitch each) body mounts on DIN rail via the clip-on mechanism, so it integrates into a standard distribution board or sub-panel as a combined RCBO assembly when paired with the matching MCB.

The 40 A rated current (In) sets the continuous load the RCD can carry without derating; it matches a 40 A MCB in the same Acti9 range, so the pair forms a coordinated RCBO. The instantaneous time delay (no intentional delay) ensures the RCD clears the fault within the standard 40 ms window, which is critical for coordination with upstream selective RCDs — the instantaneous unit trips first, leaving the upstream time-delayed device to act as backup.

Clip-on mounting on DIN rail — no tools needed for the rail attachment. The neutral position is left, so verify the orientation matches the busbar and the adjacent MCB's neutral take-off point. Bottom tunnel terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable; tighten to 2 N·m. Strip length is 14 mm for the bottom connection. The electrical connection to the MCB is by screws, so the RCD is mechanically and electrically linked to the line-side breaker. IP20 on the body (finger-safe), IP40 inside a modular enclosure — standard for distribution boards.