Schneider Electric ATV1200A6706060

Schneider ATV1200A6706060 AC Drive, 560 kW, 2970-3630 V

MPN ATV1200A6706060
Active

Schneider Electric Altivar 1200 ATV1200A6706060 medium-voltage AC drive, 560 kW, 2970-3630 V supply, 30-pulse input, 670 kVA, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A6706060 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current65 A
IP ratingIP31 / IP42 / IP41
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1400 mm (standard efficiency) 1500 mm (high efficiency)
Width2860 mm (standard efficiency) 3160 mm (high efficiency)
Height2590 mm standard efficiency 2740 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Medium-voltage drive for 560 kW motor loads

The Schneider Electric ATV1200A6706060 is a medium-voltage AC drive from the Altivar 1200 series, rated for 560 kW motor power with a supply voltage range of 2970 to 3630 V. This places it squarely in the medium-voltage drive class — not a 480 V unit — so the incoming supply and switchgear must match that voltage band. The 30-pulse diode rectifier bridge input inherently mitigates line-side harmonics below IEEE 519 thresholds without external filters — a real advantage when the plant power system has capacitor banks or sensitive loads on the same bus. Apparent power rating is 670 kVA, which sets the transformer and upstream breaker sizing. The prospective line Isc withstand is 31.5 kA for 150 ms — the upstream protection must coordinate to clear within that window.

Overload profile and duty selection

Two overload profiles are available: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload handles 1.5× In for 60 s and 1.85× In for 3 s. The high-overload curve suits applications with heavy starting or intermittent peak loads — crushers, centrifuge drives, or extruders where the motor pulls above nameplate during the process cycle. The drive supports both asynchronous and synchronous motors, so it can run a PM motor retrofit or a standard induction machine from the same unit — useful when the driven equipment changes over the plant life. Speed range is listed as 20 to 100, likely a percentage of base speed — the lower bound of 20 % means the drive can regulate down to one-fifth of rated motor speed without instability, typical for fan and pump turndown.

Enclosure, cooling, and site prep

The drive ships in a floor-standing enclosure with separate air flows for power and control sections. Dimensions vary by efficiency option: standard efficiency measures 2860 mm wide × 1400 mm deep × 2590 mm high; high efficiency adds width to 3160 mm and height to 2740 mm, depth to 1500 mm. The footprint difference matters when the drive room has fixed column spacing or a door swing arc. Cooling is forced convection requiring 16,600 m³/h for standard efficiency and 19,900 m³/h for high efficiency. The HVAC system in the drive room must handle this exhaust volume plus the heat rejection — undersized ventilation is a common commissioning delay. Acoustic noise is 80 dB — hearing protection zones and enclosure acoustic treatment should be planned for the drive room layout.

Standards compliance and isolation

The drive carries CE marking and complies with EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (adjustable speed drives), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per EN/IEC 61800-5-1 means it is rated for normal industrial environments with only non-conductive contamination — not for conductive dust or chemical spray. Electrical isolation between power and control is standard for medium-voltage drives — the control electronics ride on a separate ground reference, so the 24 V I/O loop does not share a fault path with the 3.3 kV power section. Dielectric strength is 20 kV AC between earth and power terminals — this is the hipot test voltage, not the operating voltage, and confirms the insulation system can withstand switching transients on the medium-voltage bus.

The 30-pulse topology and medium-voltage rating limit direct drop-in alternatives — no pin-compatible second source exists in the same footprint.