Schneider Electric ATV1200A85001010

Schneider Electric ATV1200A85001010 AC Drive, 7106 kW

MPN ATV1200A85001010
Active

Schneider Electric Altivar 1200 ATV1200A85001010 AC Drive (VFD) 480V, 7106 kW motor power, 8500 kVA apparent power, 48-pulse input, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A85001010 specifications
ParameterValue
Input type48 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current490 A
IP ratingIP42 / IP31 / IP41
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1700 mm (standard efficiency)
Width9370 mm (standard efficiency)
Height3040 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

What this VFD is and what it drives

The Schneider Electric ATV1200A85001010 is a medium-voltage AC drive from the Altivar 1200 family, designed for large asynchronous motors up to 7106 kW. It delivers 8500 kVA apparent power from a 2970...3630 V supply, using a 48-pulse diode rectifier bridge input topology that keeps line-side harmonics low enough to often skip an external filter.

Sizing the overload and fault handling

The drive handles 1.2× In for 60 s under standard overload, and 1.5× In for 3 s; for high-overload profiles it sustains 1.5× In for 60 s and 1.85× In for 3 s — match the duty cycle to your load profile before freezing the BOM. Prospective line short-circuit current is rated at 31.5 kA for 150 ms, and the drive includes ground-fault protection on the output side. Dielectric strength between earth and power terminals is 28 kV AC — this is a medium-voltage drive, not a 480 V unit; the supply voltage limits (2970...3630 V) confirm the class.

Physical footprint and installation constraints

The drive ships in a floor-standing enclosure measuring 1700 mm deep, 9370 mm wide, and 3040 mm high — this is a multi-cabinet lineup, not a wall-mount unit. Plan for a dedicated electrical room with overhead bus or cable trench access. Cooling is forced convection requiring 110000 m³/h of air volume — the room HVAC must handle this rejection, and the separate air-flow paths keep power-cell heat from recirculating into the control section. Noise level is 80 dB — hearing protection zones apply near the enclosure during operation. Operating altitude derating starts at 1000 m: 0.6 % per 100 m above that. The drive must be mounted vertical ±10° and the ambient relative humidity kept between 0...90 % (0...95 % with optional treatment).

Control supply and I/O architecture

The control section needs an external 220 V AC supply at 3 kVA (or optional 220 V AC/DC); the cooling fans run on a separate 380 V AC supply. Electrical isolation between power and control circuits is maintained. Standard I/O includes 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance), 1 analogue output of the same type, 6 discrete inputs (expandable to 10), and a built-in EMC filter. Main power connection uses M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom.

Standards compliance and lifecycle status

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle stage is current production — this is an active catalogue item, not a phase-out or legacy part. The ATV1200 series remains in Schneider's standard portfolio for medium-voltage drives.