Schneider Electric ATV1200A8605555

Schneider Electric ATV1200A8605555 Altivar 1200 VFD, 860 kVA

MPN ATV1200A8605555
Active

Schneider Electric Altivar 1200 series, ATV1200A8605555 medium-voltage AC drive, 860 kVA apparent power, 719 kW motor power, 30-pulse rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A8605555 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current100 A
IP ratingIP41 / IP31 / IP42
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1400 mm (standard efficiency) 1500 mm (high efficiency)
Width2860 mm (standard efficiency) 3460 mm (high efficiency)
Height2590 mm standard efficiency 2740 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Medium-voltage drive for 3.3 kV motors

The Schneider Electric ATV1200A8605555 is an Altivar 1200 medium-voltage variable frequency drive rated for 860 kVA apparent power and 719 kW motor output. It accepts a supply voltage of 2970 to 3630 V, placing it squarely on 3.3 kV class grids — common for large pumps, fans, and compressors in mining, water, and heavy industrial plants. The input stage uses a 30-pulse diode rectifier bridge, which cancels the 5th, 7th, 11th, and 13th harmonics at the line side — this avoids the need for a separate harmonic filter in most installations and keeps the total harmonic distortion (THD) low enough to meet IEEE 519 without additional hardware. The drive is assembled in a floor-standing enclosure with separate air flows for the power cells and the transformer section, allowing the forced-convection cooling system to manage the thermal load of 16,600 to 23,200 m³/h of cooling air depending on the efficiency variant.

Overload capability and duty-cycle planning

The ATV1200A8605555 offers two overload profiles: standard overload handles 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload handles 1.5× for 60 seconds and 1.85× for 3 seconds. For a 719 kW motor driving a high-inertia load like a centrifuge or a crusher, the high-overload setting gives the extra torque margin during acceleration without oversizing the drive frame. The prospective line short-circuit current withstand is 31.5 kA for 150 ms, which means the drive can ride through a bolted fault on the upstream transformer without internal damage — a critical spec for coordination studies in medium-voltage switchgear. Dielectric strength between earth and power terminals is 20 kV AC, and isolation between power and control circuits is electrical. This allows the control wiring to share a panel with sensitive instrumentation without coupling noise or risking insulation breakdown during a surge.

Physical footprint and site integration

The enclosure dimensions vary by efficiency variant: standard efficiency measures 1400 mm deep × 2860 mm wide × 2590 mm high; high efficiency adds depth to 1500 mm, width to 3460 mm, and height to 2740 mm. The operating position is vertical ±10 degrees, so the drive must sit on a level floor — no wall-mount or side-lay options. Power connections are via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase (/R, /S, L3/T), with entry from the bottom or top. The control supply requires an external 220 V AC source at 3 kVA, and the cooling fan runs on a separate 380 V AC feed — plan for two auxiliary circuits in the MCC bucket.

Standards compliance and approvals

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II confirm it is designed for clean, controlled environments — not for outdoor or condensing-humidity installations without additional shelter.

MPN