Skip to main content
Schneider Electric ATV21WD55N4C

Schneider Electric ATV21WD55N4C AC Drive, 55 kW, 380-480 V

MPN ATV21WD55N4C
Obsolete

Schneider Electric Altivar 21 ATV21WD55N4C AC drive, 55 kW, 380-480 V, 3-phase, IP20, integrated Class B EMC filter.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV21WD55N4C key specifications
ParameterValue
Connector type1 RJ45
Main product or component typeVariable speed drive
Voltage= 1 mOhm 500 V DC for 1 minute
Current89 A 480 V 102.7 A 380 V
Frequency6...16 kHz adjustable 8...16 kHz with derating factor
Phases3-phase
IP ratingIP54
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max40 °C
Temp operating min-10 °C
Storage temperature-13...158 °F (-25...70 °C)

All specifications

ATV21WD55N4C additional specifications
ParameterValue
Pollution degree3 IEC 61800-5-1
Depth14.3 in (364 mm)
Width14.3 in (362 mm)
Height39.4 in (1000 mm)
Data format8 bits, 1 stop, odd even or no configurable parity
Operating positionVertical +/- 10 degree
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

55 kW VFD for pump and fan duty

The ATV21WD55N4C is a 55 kW Altivar 21 AC drive designed for variable-torque loads like centrifugal pumps and fans. An integrated Class B EMC filter meets EN 55011 Group 1 Class B emissions limits, saving panel space and external filter cost in residential or light-industrial installations. The adjustable switching frequency ranges from 6 to 16 kHz, with a derating factor applied above 8 kHz — useful for quietening motor whine at the cost of reduced continuous output current.

Transient overtorque and speed regulation

Transient overtorque capability of 120 % nominal motor torque for 60 seconds handles short-duration overloads during pump start or fan inertia ramp-up. Speed accuracy is ±10 % of nominal slip from 0.2 Tn to Tn, and an adjustable PI regulator loop allows closed-loop process control without an external controller. The drive supports Modbus RTU over a 2-wire RS-485 physical interface at 9600 or 19200 bps, with up to 247 addresses on the bus. Optional communication cards add BACnet, LonWorks, Metasys N2, or Apogee FLN for building management integration.

Lifecycle and sourcing — mature, quoted to order

No stock-holding claim is made here.