Skip to main content
Schneider Electric ATV6000D780A6666ND

Schneider ATV6000D780A6666ND Altivar Process Drive, 780 kVA,

MPN ATV6000D780A6666ND
Active

Schneider Electric Altivar Process ATV6000, ATV6000D780A6666ND, medium-voltage drive, 3-phase, 780 kVA apparent power, 590 kW heavy duty / 620 kW normal duty motor power, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000D780A6666ND specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial
Current68.3 A normal duty 65 A heavy duty
Frequency50 Hz +/- 5 %
Phases3-phase
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature32...122 °F (0...50 °C)
Pollution degreePollution degree 2
Depth55.1 in (1400.0 mm)
Width108.7 in (2760.0 mm)
Height103.03 in (2617.0 mm)
Operating temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport

Product details

The Schneider Electric ATV6000D780A6666ND is an Altivar Process ATV6000 medium-voltage drive in a floor-standing enclosure, rated for 3-phase supply with a 30-pulse diode rectifier bridge input and IGBT multilevel PWM output. It delivers 780 kVA apparent power and handles motor loads up to 620 kW normal duty or 590 kW heavy duty. Line current is 68.3 A normal duty, 65 A heavy duty, with total harmonic current distortion below 3% per IEEE 519-1992. Power factor sits at 96%.

The 30-pulse input topology keeps input harmonics low enough to meet IEEE 519 without external filters in most installations — the <3% THDI figure is the headline. The integrated EMC filter covers IEC 61800-3 category C3 on the control side and C4 on the power side, which means the drive is intended for industrial environments with a separate transformer or dedicated supply. The 10-inch LCD touchscreen HMI is multi-language and supports local commissioning and fault diagnostics. Three configurable relay outputs (R1 fault, R2 and R3 sequence) and eight programmable digital inputs are on the control block, plus two RJ45 ports for Ethernet IP/Modbus TCP and one for Modbus serial. Option card slots A and B accept a range of fieldbus modules (Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT) and encoder interfaces (digital, analog, resolver, HTL), plus digital/analog I/O and relay extension modules. Slot selection determines network integration — plan the communication protocol before ordering.

Compliance & environment

Marked CULus, CE, UKCA. Designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A. Pollution degree 2 per IEC 61800-5-1. Ambient relative humidity 5–95% non-condensing. Noise level is 80 dB — this is a forced-convection-cooled drive in a floor-standing cabinet; plan for acoustic enclosure or hearing protection if the drive is in a manned area. Power losses are 27 kW normal duty, 25.7 kW heavy duty, so ventilation or air conditioning in the room must handle that heat load.

MPN