Skip to main content
Schneider Electric ATV6A0C50T6

Schneider ATV6A0C50T6 ATV600 Drive, 550 HP, STO SIL3

MPN ATV6A0C50T6
Active

Schneider Electric Altivar Process ATV600, modular version, 550 hp normal duty / 450 hp heavy duty at 600 V, 464 A normal duty line current, integrated EMC filter Category C3, Safe Torque Off SIL 3, cabinet mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6A0C50T6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current464.0 A 600 V normal duty) 383.0 A 600 V heavy duty)
Horsepower550.0 hp at 600 V normal duty 450.0 hp at 600 V heavy duty
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

Rating breakdown: normal vs heavy duty

The ATV6A0C50T6: The normal duty curve (550 hp, 464 A) suits constant-torque or variable-torque loads with moderate overloads. The heavy duty curve (450 hp, 383 A) provides higher overload capacity – typically for conveyors, crushers, or extruders. The 8 kVA gap between the two duty points (482 vs 398 kVA) reflects the headroom the drive reserves for transient overloads. Select based on the motor's peak torque demand, not just the nameplate horsepower.

Safety and EMC integration

STO (Safe Torque Off) rated SIL 3 per IEC 61508 / IEC 13849-1 is standard – no separate safety module required for removal of torque. The integrated EMC filter covers 300 m of motor cable to Category C3, which is sufficient for most industrial environments; for longer runs or Category C2 installations an external filter is needed. Pollution degree 2, vibration and shock per IEC 60068-2-6/11 ms, altitude up to 2000 m with derating above 1000 m. Standards compliance includes IEC 61800-3, UL 61800-5-1 (Type 1/12 enclosure), and IEC 61000-3-12 (THDI <48% at full load).

Cabinet mounting notes

Cabinet mount only – no standalone enclosure rating. The kit composition includes the control unit, mechanical mounting kits, power connection set of fuses, and a 200 kW power module with front cover. Line side termination uses M10 x 2 bars; control wiring is via removable screw terminals (0.5–1.5 mm² / AWG 20–16). Forced convection cooling means clear airflow around the heatsink – maintain the manufacturer's minimum clearance. Slot A accepts one communication option card; Slot B is available for I/O or relay extensions. Prospective line Isc is 50 kA – coordinate upstream fuses or breakers accordingly.

Sourcing posture

The ATV6A0C50T6 is an active, current-production part (lifecycle stage: current). No obsolescence horizon announced. This is a large-drive SKU (550 hp class), typically quoted to order rather than held available via RFQ confirmation at distribution. Lead time depends on factory load and configuration – submit an RFQ for a firm delivery commitment. For BOM planning, treat it as a standard lead-time item with no risk of last-time buy.

MPN
ATV6A0C50T6