Skip to main content
Schneider Electric C10F1TM025

Schneider C10F1TM025 ComPacT NSX100F MCCB, 25 A, 18 kA

MPN C10F1TM025
Active

Schneider Electric, ComPacT NSX series, NSX100F circuit breaker, C10F1TM025, 1-pole, 25 A thermal-magnetic trip unit, 18 kA Icu at 240 V AC.

$74.43 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10F1TM025 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage277 V AC 50/60 Hz 250 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity18 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10F1TM025 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width35 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It provides L (overload) and I (short-circuit) protection in a single-pole (1P) fixed-mount package for distribution applications. Rated breaking capacity hits 18 kA Icu at 220/240 V AC (50/60 Hz) and 36 kA Icu at 250 V DC, both per IEC 60947-2. If your panel runs hotter, you'll need to derate per the thermal curve — the 40 °C figure is the baseline, not a guarantee at 50 °C.

Fixed-mount on a backplate, 35 mm wide, 161 mm tall, 86 mm deep. Front-connect on both line and load sides — no rear-access needed, which simplifies panel layout. Toggle control, no aux contacts or shunt trip included as standard.

Mechanical endurance is 20,000 cycles; electrical endurance is 20,000 cycles at 277 V at In/2 and 10,000 cycles at 277 V at full In. Suitability for isolation is confirmed per EN/IEC 60947-2 — you can use it as a disconnecting means for safe maintenance. Power dissipation per pole is 4.01 W. For a 1-pole breaker that's 4 W of heat to vent in the enclosure — negligible for a single unit, but add up the row in a multi-breaker panel.

MPN
C10F1TM025