Skip to main content
Schneider Electric C10M2TM025

Schneider Electric C10M2TM025 ComPacT NSX Circuit Breaker, 2

MPN C10M2TM025
Active

Schneider Electric ComPacT NSX, circuit breaker, 25 A, 2P, thermal-magnetic TM-D trip unit, 85 kA Icu at 220/240 V AC, fixed mount, IP40.

$118.70 – $163.29 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10M2TM025 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz 500 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 18 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 85 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10M2TM025 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width70 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C10M2TM025 is a Schneider Electric ComPacT NSX100M moulded-case circuit breaker, 2-pole, with a fixed thermal-magnetic TM-D trip unit rated 25 A at 40 °C. At 415 V AC the breaking capacity is still 25 kA Icu, which covers most European distribution boards.

Mounts fixed to a backplate — no DIN-rail adapter here. The 70 mm width and 161 mm height fit the standard ComPacT NSX cutout; depth is 86 mm, which leaves room for front-facing cable connections on both line and load sides. IP40 enclosure protection means it is fine inside a cabinet but not for washdown environments.

No end-of-life notice or successor has been issued. No second-source or cross-reference exists within the ComPacT family that matches the exact 25 A TM-D 2P configuration without a trip-unit swap.

What the trip unit does

The thermal element responds to sustained overcurrents; the magnetic element trips instantaneously on high fault currents. No earth-leakage protection is built in — that requires a separate Vigi add-on or an external RCD. Power dissipation is 4.01 W per pole, so for a 2-pole breaker expect about 8 W of heat inside the enclosure at rated load.

MPN
C10M2TM025