Skip to main content
Schneider Electric C10N34V100

Schneider C10N34V100 ComPacT NSX 100A Earth Leakage Breaker,

MPN C10N34V100
Active

Schneider Electric ComPacT NSX, C10N34V100, earth leakage circuit breaker, 100 A, 3P, MicroLogic 4.2 trip unit, 50 kA Icu at 415 V AC.

$1,045.80 – $1,995.84 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10N34V100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10N34V100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider C10N34V100 is a ComPacT NSX earth leakage circuit breaker, 3-pole, rated 100 A at 40 °C with a MicroLogic 4.2 electronic trip unit. The 90 kA Icu at 240 V AC is the same breaker on a lower-voltage service; the 10 kA at 690 V AC is the ceiling for a 690 V line. What governs the real-world fit is the 100 A trip unit rating and the integrated earth-leakage protection (the R in the protection type set: L for overload, So for short-time short-circuit with fixed delay, I for instantaneous short-circuit, R for earth-leakage). The electronic trip gives you adjustable long-time pickup and delay, plus the earth-leakage function built in — no add-on module needed.

Mounts to a backplate — not a DIN rail. The 105 mm width (3-pole frame) and 161 mm height fit standard ComPacT NSX cutouts; the 86 mm depth leaves room for front-connected cables (upside and downside connections are both front-facing). The IP40 front face keeps dust out; the IK07 impact rating handles accidental tool drops during commissioning. The 35 mm connection pitch is the standard busbar or cable-lug spacing for this frame size.

What the durability numbers mean for a distribution feeder

Mechanical durability is 50,000 cycles — that is the handle life, not the electrical contact life. Electrical durability varies by load: 50,000 cycles at 440 V at half rated current (In/2), 30,000 cycles at 440 V at full rated current (In), 20,000 cycles at 690 V at In/2, and 10,000 cycles at 690 V at In. For a distribution feeder that sees infrequent switching (a few operations a year), these numbers are academic — the breaker will outlast the panel. But if this breaker is used as a disconnect that cycles weekly, the 30,000-cycle figure at 440 V In is the one to watch.

MPN
C10N34V100