Schneider Electric C10V46E100

C10V46E100 ComPacT NSX 100A 4P MicroLogic 6.2 E, 85kA

MPN C10V46E100
Active

Schneider Electric ComPacT NSX, NSX100HB1, 100 A at 40 °C, 4P, MicroLogic 6.2 E electronic trip unit, 85 kA Icu at 500 V AC, EN/IEC 60947-2.

$1,252.64 – $1,356.96 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10V46E100 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C10V46E100 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It's rated 100 A at 40 °C, 4 poles, and carries an 85 kA Icu breaking capacity at 500 V AC 50/60 Hz per IEC 60947-2. The 6.2 E trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection — the 'E' designation means it includes energy metering and power quality measurement, not just protection. This is a distribution-grade device (Category A) for backplate mounting, with front connections both top and bottom.

The HB1 breaking capacity code means 75 kA Icu at 690 V AC, but the full curve is 85 kA at 500 V, 80 kA at 525 V, and 75 kA at 660/690 V. For a 480 V or 400 V distribution panel, that 85 kA Icu at 500 V gives substantial headroom above typical utility fault levels. The 4-pole frame with neutral on the left handles 3-phase plus neutral distribution without a separate neutral breaker. The 20,000-cycle mechanical durability and 20,000-cycle electrical durability at 440 V In/2 (10,000 at full In) are typical for a panelboard main or feeder breaker — not a daily-switched disconnect, but fine for infrequent manual operation.

Trip unit and metering

The MicroLogic 6.2 E is an electronic trip unit with an LCD display and local signalling: a flashing green LED for ready, red LED at 105% Ir for overload, orange at 90% Ir. It communicates instantaneous and demand values, protection and alarm settings, power quality, energy metering, maintenance indicators, and time-stamped event tables.

Connection pitch is 35 mm. Pollution degree 3 per IEC 60664-1, overvoltage category III, operating altitude 0–2000 m without derating, 2000–5000 m with derating. Relative humidity 0–95%. IK07 impact protection per IEC 62262. The toggle control and LCD display are front-accessible.

MPN
C10V46E100