Skip to main content
Schneider Electric C11E34V025B

C11E34V025B ComPacT NSXm Earth Leakage Circuit Breaker, 25 A

MPN C11E34V025B
Active

Schneider Electric ComPacT NSXm earth leakage circuit breaker, 25 A rated, 3-pole, MicroLogic 4.1 electronic trip unit, 16 kA breaking capacity at 415 V AC, grey (RAL 7016).

$1,258.74 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11E34V025B key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11E34V025B additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryE 16 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11E34V025B is a ComPacT NSXm earth leakage circuit breaker with a MicroLogic 4.1 electronic trip unit. It's rated 25 A at 40 °C, three-pole, and carries a 16 kA breaking capacity at 415 V AC — that's the fault level it can safely clear without welding contacts or venting gas into the panel.

The 25 A rating at 40 °C is the continuous current the breaker handles in a 40 °C ambient — push it into a warmer enclosure and you'll need to derate per the thermal curve. The electronic trip unit (MicroLogic 4.1) gives you adjustable overload and short-circuit protection curves, plus integrated earth-leakage protection with selectable sensitivity from 30 mA to 5 A, Class A or AC. That means one device covers both overcurrent and ground-fault protection — saves a slot in the panel. That means it's rated for motor-starting duty and higher fault levels than a typical DIN-rail MCB.

It's 9 module pitches wide (108 mm), 144 mm tall, 80 mm deep. Front connections top and bottom accept compression lugs or busbars. The 35 mm connection pitch with spreaders (27 mm without) matches standard busbar systems.

MPN
C11E34V025B