Skip to main content
Schneider Electric C125N42EFM

C125N42EFM ComPacT NS 1250A 4P MCCB, 85 kA at 240 V

MPN C125N42EFM
Active

Schneider Electric ComPacT NS new generation, C125N42EFM, 4P MCCB with MicroLogic 2.0 E electronic trip unit, 1250 A, 85 kA Icu at 240 V AC, manually operated, fixed mount.

$2,927.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C125N42EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C125N42EFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C125N42EFM is a Schneider Electric ComPacT NS new generation moulded-case circuit breaker (MCCB) from the NS630b...1600 range, rated 1250 A at 50 °C with a MicroLogic 2.0 E electronic trip unit. At 415 V the rating holds at 50 kA, still well above typical industrial service-entrance requirements. The MicroLogic 2.0 E provides L (long-time overload) and I (instantaneous short-circuit) protection curves, with a 20-minute thermal memory that prevents nuisance tripping on re-energisation after a hot overload. The electronic trip unit gives better accuracy and repeatability than thermal-magnetic alternatives, especially across ambient temperature swings.

Fixed backplate mount, 327 mm high by 280 mm wide by 147 mm deep — sized for a standard MCC bucket or standalone enclosure. Front connection both top and bottom, with a 70 mm connection pitch that matches common busbar and cable-lug patterns. IK07 impact rating handles accidental tool drops during panel work. Neutral is on the left, which matters when wiring a 4-pole breaker into an existing bus run — verify your busbar phasing matches before landing lugs.

MPN
C125N42EFM