Skip to main content
Schneider Electric C12N44V160B

C12N44V160B ComPacT NSXm 160A 4P MCCB, 50kA 415V AC

MPN C12N44V160B
Active

Schneider Electric ComPacT NSXm, C12N44V160B, 4P 160A MCCB, 50kA at 415V AC, MicroLogic 4.1 electronic trip unit, integrated earth-leakage, IP40, grey RAL 7016.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C12N44V160B key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C12N44V160B additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryN 50 kA 415 V AC
Operating temperature-25...70 °C

Product details

What this MCCB is and what the ratings mean for fit

The C12N44V160B is a Schneider Electric ComPacT NSXm moulded-case circuit breaker (MCCB) in a 4-pole (4P) configuration, rated 160 A at 40 °C and designed for distribution duty on AC networks at 50/60 Hz. Its headline breaking capacity is 50 kA at 415 V AC — that is the maximum fault current it can safely interrupt without welding contacts or rupturing the case, which determines whether it can be placed upstream of a panel with a high available fault current. The electronic MicroLogic 4.1 trip unit provides adjustable overload and short-circuit protection with an integrated earth-leakage function selectable from 30 mA up to 5 A, covering both class A and class AC residual current types. That means this single device can serve as both a feeder breaker and a ground-fault protector, reducing component count in a distribution panelboard.

Compliance and documentation

The MCCB is certified to EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear — specifically the circuit-breaker product standard. Pollution degree 3 per IEC 60664-1 means it is rated for a conductive environment (typical of industrial control panels), and overvoltage category IV suits it for main distribution boards at the service entrance. Operating altitude is 2000 m without derating; above that up to 5000 m requires derating per the manufacturer's curve. Relative humidity range is 0–95% non-condensing. The thermal memory function retains heat history for 20 minutes before and after tripping, preventing immediate reclosure on a hot overload — a detail that matters for motor feeder applications where repeated starts could otherwise nuisance-trip.

MPN
C12N44V160B