Skip to main content
Schneider Electric C160H35EFM

Schneider C160H35EFM ComPacT NS 1600A 3P MCCB, 85kA Icu

MPN C160H35EFM
Active

Schneider Electric ComPacT NS new generation, C160H35EFM, 3P 1600 A MCCB, 85 kA Icu at 240 V AC, MicroLogic 5.0 E electronic trip unit, fixed mount, IP40.

$3,939.20 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H35EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront

All specifications

C160H35EFM additional specifications
ParameterValue
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It is a manually operated, fixed-mount 3-pole breaker rated 1600 A at 50 °C, with an electronic MicroLogic 5.0 E trip unit that provides L (long-time overload), S (short-time short-circuit), and I (instantaneous short-circuit) protection plus integrated energy metering.

Rated 85 kA Icu at 220/240 V AC, 70 kA Icu at 380/415 V AC, and 42 kA Icu at 660/690 V AC per IEC 60947-2. That 70 kA at 415 V gives solid selectivity headroom in a 400 V distribution panel — downstream breakers can coordinate without nuisance tripping on a bolted fault.

Trip unit and metering

It includes an energy meter — so you get load profiling and power data without a separate meter module. The thermal memory holds for 20 minutes after a trip, which means the breaker remembers the heat profile if you reclose quickly; useful for motor or transformer feeders that see repeated starts.

Fixed mount on a backplate, 210 mm wide × 327 mm high × 147 mm deep. Connection pitch is 70 mm, with front-facing upside and downside connections — that keeps cable entry and exit on the same plane, simplifying busbar or cable routing in a switchboard. IP40 front face, IK07 impact rating.

MPN
C160H35EFM