Schneider Electric C160H460FM ComPacT NS Circuit Breaker, 16

MPN C160H460FM
Active

Schneider Electric ComPacT NS new generation, C160H460FM, 4P circuit breaker, 1600 A at 50 °C, MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, fixed mount, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H460FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C160H460FM additional specifications
ParameterValue
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C160H460FM is a ComPacT NS new generation 4-pole fixed-mount circuit breaker with a MicroLogic 6.0 electronic trip unit, rated 1600 A at 50 °C. It is a manually operated distribution breaker built to EN/IEC 60947-2 standard, with an ultimate breaking capacity (Icu) of 85 kA at 220/240 V AC and 70 kA at 380/415 V AC. The 1600 A frame means this is sized for a main or heavy feeder in a low-voltage switchboard, not a branch circuit — expect to see it on the incoming side of a large distribution panel or as a tie breaker in a high-current bus.

The MicroLogic 6.0 electronic trip unit provides four protection curves: L (long-time overload), S (short-time short circuit), I (instantaneous short circuit), and G (ground fault). That G function is critical for personnel protection in grounded systems; it's not just an equipment safeguard. The 4-pole version with neutral on the left is standard for three-phase plus neutral distribution, and the fixed mount with backplate support means it bolts directly into a switchboard, not a DIN rail.

Integration and physical fit

The breaker measures 327 mm high by 280 mm wide by 147 mm deep — check your enclosure depth before committing. IK07 impact rating means it can withstand a 2 J impact, so it's reasonably robust for a switchboard environment.

Electrical durability and diagnostics

Mechanical durability is rated at 10,000 cycles; electrical durability varies by load — 1,000 cycles at full rated current at 690 V, up to 5,000 cycles at half current at 440 V. The MicroLogic 6.0 trip unit includes four red LEDs for fault indication (one each for L, S, I, G trip causes) and a yellow LED for overload pre-alarm. That's a real time-saver during commissioning or fault-finding — you get a direct visual on what caused the trip without needing a laptop or software. The thermal memory (20-minute reset) prevents immediate reclosure after an overload, which protects the downstream cable and load from repeated thermal stress.