Skip to main content
Schneider Electric C16B32D160

Schneider Electric C16B32D160 ComPacT NSX160B, 160 A, 3P, Mi

MPN C16B32D160
Obsolete

Schneider Electric ComPacT NSX, NSX160B, circuit breaker, 160 A, 3P, MicroLogic 2.2 electronic trip unit, 40 kA Icu at 240 V AC.

$368.61 – $948.83 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16B32D160 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C16B32D160 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C16B32D160 is a Schneider Electric ComPacT NSX160B moulded-case circuit breaker, rated 160 A at 40 °C with a MicroLogic 2.2 electronic trip unit. The 40 kA Icu at 240 V AC is the maximum fault current it can safely interrupt once; the 25 kA at 415 V AC is the more relevant number for a 400 V distribution panel. The MicroLogic 2.2 trip unit provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection curves. That matters on a conveyor or compressor with repetitive overload cycles.

Mounts flat on a backplate in either horizontal or vertical orientation — no derating required for position. Front-connect on both line and load sides, with a 35 mm connection pitch that matches standard busbar systems. The 105 mm width and 161 mm height fit a standard 3-pole MCCB cutout; depth of 86 mm leaves room for rear-access wiring in a 400 mm deep enclosure. Five accessory slots accept auxiliary contacts, shunt trips, undervoltage releases, or communication modules (Modbus, Ethernet) without increasing the breaker footprint. The toggle handle provides local manual operation with clear ON/OFF indication.

MPN