Skip to main content
Schneider Electric C16F3MA100

Schneider Electric C16F3MA100 ComPacT NSX160F, 100 A, 85 kA

MPN C16F3MA100
Active

Schneider Electric ComPacT NSX NSX160F, circuit breaker, 3P, 100 A at 65 °C, MA magnetic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16F3MA100 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C16F3MA100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

It is designed specifically for motor protection — the MA trip provides short-circuit protection (magnetic) only, with no thermal overload element, so it coordinates with an external motor starter or overload relay.

The MA trip unit is magnetic-only, so it responds to short-circuit currents but does not provide thermal overload protection; that is left to the motor starter or soft starter downstream. At 480 V AC the Icu is 35 kA (UL 60947-4-1), and at 600 V AC it drops to 10 kA — still sufficient for many 480 V motor loads. The 3-pole, 3D protected poles configuration means all three poles are protected against short circuits.

The toggle control gives clear visual indication of ON/OFF/TRIPPED status. IP40 front face and IK07 impact resistance handle typical panel conditions.

MPN