Skip to main content
Schneider Electric C16L4

C16L4 ComPacT NSX160L Basic Frame, 160A 4P, 150kA/415V

MPN C16L4
Active

Schneider Electric ComPacT NSX160L basic frame, C16L4, 160 A frame rating, 4 poles, 150 kA Icu at 415 V AC, without trip unit, fixed mount, toggle control.

$432.93 – $1,129.09 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16L4 key specifications
ParameterValue
Control typeToggle
Protection typeWithout protection
Main product or component typeBasic frame
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C16L4 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2 15000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 7500 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2
Mechanical life cycles40000 cycles conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What the 160 A frame and 130 kA Icu mean for your panel

The 160 A frame rating at 40 °C sets the continuous current capacity; cable and busbar sizing start from this number. The 130 kA Icu at 440 V AC (150 kA at 380/415 V) is the ultimate short-circuit breaking capacity per IEC 60947-2 — this is the SCCR that governs selectivity with the upstream breaker and determines whether the panel meets the fault-current requirement without cascading. The frame also carries a 150 kA Ics (service breaking capacity) at 380/415 V, meaning it can reclose after clearing that fault level without immediate replacement. This is a basic frame — it ships without a trip unit. The buyer must order the electronic or thermal-magnetic trip unit separately and install it into the frame. The 4-pole configuration with neutral on the left suits distribution panels where full-phase plus neutral switching is required.

Standards and approvals — IEC and UL on the same label

The C16L4 is dual-listed to EN/IEC 60947-2 (low-voltage switchgear and controlgear — circuit-breakers) and UL 60947-4-1 (motor-protective circuit-breakers). This single part covers panel builds destined for IEC markets (Europe, Asia, Middle East) and UL-recognized installations (North America). The front face carries Class II shock protection — no earth connection required on the operator-facing side.

Mounting and integration — backplate fixed, front connections

Fixed mounting on a backplate, not DIN-rail. The 140 mm width, 161 mm height, and 86 mm depth define the cutout and enclosure space — plan for a 4-pole MCCB footprint with front-facing connections on both line and load sides. The toggle control is front-accessible; the IK07 impact rating means the front face withstands a 2 J hammer blow typical of panel-door installations. IP40 protection keeps out tools and wires over 1 mm but not dust — mount inside a sealed enclosure for dusty environments.

MPN