Skip to main content
Schneider Electric C25B34V160

Schneider C25B34V160 ComPacT NSX Earth Leakage Breaker, 160

MPN C25B34V160
Obsolete

Schneider Electric ComPacT NSX, earth leakage circuit breaker, 3P, 160 A, MicroLogic 4.2 trip unit, 25 kA Icu at 415 V AC, IP40, backplate mount.

$1,164.41 – $2,511.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25B34V160 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C25B34V160 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It carries the MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection — the R protection function is built in, not an add-on module. Breaking capacity is 25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, sufficient for most distribution panelboard fault levels in commercial and light industrial installs. The B in the order code (C25B34V160) maps to that 25 kA class at 415 V.

160 A frame with a 160 A trip unit sized for 160 A continuous load. MicroLogic 4.2 provides L, So, I, and R protection curves in one electronic trip unit. Integrated earth-leakage saves a panel slot. For selectivity coordination downstream, the fixed-delay So curve lets you hold for a short interval so branch breakers clear first. Backplate mount, horizontal or vertical. Overvoltage category IV means it's suitable for main distribution boards, not just sub-panels.

Integration notes

Mounts on a backplate — no DIN rail adapter. 105 mm wide, 161 mm high, 86 mm deep. Front connections both upside and downside. The toggle handle is the control interface; the IΔn rotary switch sets the earth-leakage threshold. Five accessory slots available for auxiliary contacts, shunt trips, or motor operators. Electrical durability: 20,000 cycles at 440 V at half rated current, 10,000 cycles at full rated current. Mechanical durability: 20,000 cycles. That's typical for a distribution breaker — not a switching device for frequent motor starts.

MPN
C25B34V160