Skip to main content
Schneider Electric C25B44B240

Schneider Electric C25B44B240 ComPacT NSX 250B 240A MCCB, 25

MPN C25B44B240
Active

Schneider Electric ComPacT NSX 250B, 4P, 240 A, MicroLogic 4.2 AB electronic trip unit, 25 kA Icu at 415 V AC, integrated earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25B44B240 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C25B44B240 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationSpecial application
Operating temperature-25...70 °C

Product details

The Schneider Electric C25B44B240 is a ComPacT NSX 250B moulded-case circuit breaker rated 240 A, 4-pole, with a MicroLogic 4.2 AB electronic trip unit. It is designed for special applications requiring integrated earth-leakage protection (R) alongside overload (L), short-time short-circuit (So), and instantaneous short-circuit (I) protection — all in one device. The B breaking capacity code means 25 kA Icu at 415 V AC, 50/60 Hz per IEC 60947-2. At 240 V AC it delivers 40 kA Icu; at 440 V AC it holds 20 kA Icu.

The 4-pole unit occupies a 140 mm width, 161 mm height, 86 mm depth footprint. IP40 enclosure protection, IK07 impact resistance. Pollution degree 3, overvoltage category IV — suited for industrial panels where conductive dust and transient overvoltages are present. Ambient humidity range 0–95 %.

Durability and signalling

Rated for 20,000 mechanical cycles and 20,000 electrical cycles at 440 V In/2, 10,000 cycles at 440 V In, 10,000 cycles at 690 V In/2, and 5,000 cycles at 690 V In. The electrical durability figures are per IEC 60947-2 utilisation category A. Local signalling includes a flashing green LED for ready-to-operate, a red LED at 105 % Ir for overload, and an orange LED at 90 % Ir for pre-alarm. The OFF operating mode uses the IΔn rotary switch for earth-leakage reset and test.

MPN