Skip to main content
Schneider Electric C25B44V160

Schneider Electric C25B44V160 ComPacT NSX 160A MCCB, 25kA 41

MPN C25B44V160
Active

Schneider Electric, ComPacT NSX, MCCB, C25B44V160, 160 A, 4P, 25 kA Icu at 415 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection.

$1,302.87 – $2,756.16 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25B44V160 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C25B44V160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C25B44V160 is a 160 A, 4-pole (4P) ComPacT NSX moulded-case circuit breaker from Schneider Electric. The 160 A trip unit rating at 40 °C sets the continuous current limit for a distribution feeder — size the upstream conductor and downstream load for that ampacity. The 'R' function is integrated, so this breaker handles both overcurrent and ground-fault protection in one device — no separate Vigi module needed. Breaking capacity: 40 kA Icu at 240 V AC, 25 kA Icu at 415 V AC, 20 kA at 440 V, and 15 kA at 500 V.

Deployment context

Mounts on a backplate in any orientation — horizontal, vertical, or flat. The 140 mm width, 161 mm height, and 86 mm depth fit standard distribution panel cutouts. IP40 enclosure protection means it's suited for indoor, clean-environment panels; the IK07 impact rating withstands incidental tool contact during installation.

Covers breaking capacity ratings, utilisation category A, and overvoltage category IV.

MPN
C25B44V160