Skip to main content
Schneider Electric C25H32D160

Schneider Electric C25H32D160 ComPacT NSX250H, 160 A, 100 kA

MPN C25H32D160
Active

Schneider Electric ComPacT NSX250H, C25H32D160, 3P 160 A circuit breaker with MicroLogic 2.2 electronic trip unit, 100 kA Icu at 240 V AC, IP40, backplate mount.

$512.04 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25H32D160 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C25H32D160 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C25H32D160 is a Schneider Electric ComPacT NSX250H 3-pole circuit breaker rated 160 A at 40 °C, fitted with a MicroLogic 2.2 electronic trip unit providing L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection per EN/IEC 60947-2. Its 100 kA Icu at 240 V AC (70 kA at 415 V, 65 kA at 440 V, 50 kA at 500 V, 35 kA at 525 V, 10 kA at 690 V) gives substantial fault-current headroom for distribution panels where high available fault current is a concern. The 20-minute thermal memory before and after tripping prevents nuisance reclosing on a hot conductor — a detail that matters when coordinating with downstream devices on motor-starting or welding loads.

The 160 A trip-unit rating sets the continuous current limit at 40 °C; above that ambient, derate per the manufacturer's curve. The MicroLogic 2.2 is an electronic trip — adjustable long-time pickup and delay, plus fixed short-time and instantaneous thresholds — so it offers coordination flexibility that a thermal-magnetic breaker cannot. The 3-pole 50/60 Hz AC network rating suits it for three-phase distribution in commercial and industrial switchboards.

Backplate-mounted with front connections — the 105 mm width and 161 mm height fit standard ComPacT NSX cutouts. IK07 impact resistance handles accidental tool drops during commissioning.

MPN