Schneider Electric C40F44B400

Schneider Electric C40F44B400 ComPacT NSX400F, 400 A, 40 kA

MPN C40F44B400
Active

Schneider Electric ComPacT NSX, NSX400F, molded case circuit breaker, 400 A, 40 kA Icu at 240 V AC, 4P, MicroLogic 4.3 AB electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C40F44B400 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C40F44B400 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width185 mm
Height255 mm
Electrical life cycles12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationSpecial application
Operating temperature-25...70 °C

Product details

The Schneider Electric C40F44B400 is a ComPacT NSX400F molded case circuit breaker (MCCB) rated 400 A at 40 °C, with a 4-pole configuration and an electronic MicroLogic 4.3 AB trip unit. Its breaking capacity is 40 kA Icu at 240 V AC per IEC 60947-2, with a stepped curve down to 10 kA at 690 V AC — the 36 kA at 415 V AC is the figure most relevant for European 400 V distribution panels.

The F breaking capacity code (36 kA at 415 V AC) places this MCCB in the middle tier of the NSX range — above the B (25 kA) and below the N (50 kA) or H (70 kA) frames. For a 400 A feeder in a 400 V industrial panel, 36 kA Icu gives headroom for most transformer-fed installations without stepping up to a larger frame. The UL 60947-4-1 ratings (85 kA at 240 V, 35 kA at 480 V) confirm suitability for North American motor branch circuits as well.

The earth-leakage function is integrated, so no external RCD or toroid is needed for ground-fault detection.

IP40 enclosure protection means it's suitable for clean indoor panels but not washdown areas.

MPN
C40F44B400