Schneider Electric C40N32M320 ComPacT NSX400N, 320 A, 85 kA

MPN C40N32M320
Active

Schneider Electric ComPacT NSX, NSX400N, circuit breaker, 3P, 320 A at 65 °C, 85 kA Icu at 240 V AC, MicroLogic 2.3 M electronic trip unit, motor protection application.

$847.57 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C40N32M320 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C40N32M320 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The C40N32M320: The 85 kA Icu at 240 V AC and 50 kA at 415 V AC mean this breaker can safely interrupt a fault current up to those levels without welding contacts or rupturing the housing. At 690 V AC it still holds 10 kA Icu. For a motor protection circuit on a 480 V supply (common in North American plants), the 50 kA Icu at 480 V AC per UL 60947-4-1 covers most service-entrance and downstream feeder applications — you won't need a current-limiting fuse upstream unless the available fault current exceeds that figure.

Motor protection trip curve and thermal memory

The MicroLogic 2.3 M provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous) protection, with selectable motor tripping classes 5, 10, and 20. The 20-minute thermal memory before and after tripping means the breaker 'remembers' prior heating — critical for motor starts in quick succession where a cold-start trip curve would allow a second start that a hot motor shouldn't get. This prevents nuisance trips on restart while still protecting the motor winding.

MPN
C40N32M320