Skip to main content
Schneider Electric C40N47E400

Schneider Electric C40N47E400 ComPacT NSX400N, 400 A, 85 kA

MPN C40N47E400
Obsolete

Schneider Electric ComPacT NSX, NSX400N, 400 A, 85 kA Icu at 240 V AC, MicroLogic 7.3 E electronic trip unit, 4P, toggle control, LCD display.

$2,670.74 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C40N47E400 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C40N47E400 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth110 mm
Width185 mm
Height255 mm
Electrical life cycles12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C40N47E400 is a ComPacT NSX400N molded-case circuit breaker with a 400 A MicroLogic 7.3 E electronic trip unit, built for distribution duty in commercial and industrial switchboards. The 85 kA Icu at 240 V AC (50/60 Hz) per IEC 60947-2 tells you this breaker can safely interrupt a fault current up to that level without welding or rupturing — that's the short-circuit withstand that decides whether it holds on a high-fault panel or lets the arc flash through. At 415 V AC the same rating drops to 50 kA Icu, which is still a strong number for a 400 A frame; at 690 V AC it holds 10 kA Icu, enough for most 690 V distribution but not for high-fault motor centers at that voltage. The MicroLogic 7.3 E trip unit gives you four protection curves in one package: L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage). That means this single breaker covers both overcurrent and ground-fault protection without an external relay — a common spec for main or feeder breakers where you need coordinated tripping downstream. The trip unit is electronic, so it holds its curve tighter than a thermal-magnetic over temperature swings, and it includes thermal memory that remembers the last 20 minutes of heating before and after tripping, which prevents nuisance reclose on a hot cable. The LCD display on the front gives you local readout of instantaneous and demand values, energy metering, and time-stamped event histories — useful for a panel that doubles as a sub-metering point. The toggle control and the IΔn rotary switch for earth-leakage OFF position let an operator isolate the R function without killing the main breaker, which is handy during commissioning or fault-finding.

Neutral is on the left, which matters when you're laying out bus bars or cable ladders — mirror the arrangement if you're replacing an older frame with neutral on the right. The 45 mm connection pitch is standard for busbar tap-offs in this frame size.

Availability and current pricing are confirmed at quote time — the 400 A frame and MicroLogic 7.3 E are common enough that lead times tend to be reasonable, but the N breaking capacity (50 kA at 415 V) is a specific variant that may not sit on every distributor's shelf. Submit an RFQ for a firm delivery date.

MPN