Schneider Electric C60H2P16AD

Schneider Electric C60H2P16AD Multi9 MCB, D Curve, 16 A, 1P+

MPN C60H2P16AD
Obsolete

Schneider Electric Multi9 C60H series, C60H2P16AD, miniature circuit breaker, D curve, 16 A, 1P+N, 10-30 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H2P16AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width36 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H2P16AD is a Multi9 C60H miniature circuit breaker with a D tripping curve, rated 16 A at 40 °C and built for 1P+N (one protected pole plus switched neutral) distribution duty. Breaking capacity runs 30 kA Icu at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC — all per IEC 60947-2. That 10 kA at 440 V is the number to watch if this breaker lands in a 400 V three-phase panel feeding a single-phase subfeed; the 15 kA at 400 V gives a bit more headroom for higher fault-current locations. The 25 kA Icu at 125 V DC (2-pole series connection) means it can also serve DC control circuits or battery-backed buswork, though the 1P+N form factor limits DC use to the 2-pole wiring method.

Snaps onto 35 mm symmetrical DIN rail — standard for any European-spec enclosure. At 36 mm wide (4 x 9 mm pitches) and 81 mm tall, it occupies one standard MCB slot plus the neutral pole width; the 73 mm depth leaves clearance behind a 100 mm deep gland plate. The neutral position is left, which matters when ganging multiple breakers on a busbar — verify the busbar lug aligns before torquing down.

Rated for operation from -25 °C to 60 °C ambient, storage from -40 °C to 70 °C, and 95 % relative humidity at 55 °C — fine for most indoor panel environments including non-condensing washdown zones. Operating altitude is 2000 m; above that, dielectric withstand and breaking capacity derate per IEC 60947-2.

MPN
C60H2P16AD