Schneider Electric C60H3P20AB

Schneider C60H3P20AB MCB, 3P 20A Curve B, 10kA

MPN C60H3P20AB
Obsolete

Schneider Electric Multi9 C60H, miniature circuit breaker, 3 poles, 20 A rated current, B curve, 10 kA breaking capacity at 440 V AC, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P20AB specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H3P20AB is a 3-pole miniature circuit breaker from Schneider Electric's Multi9 C60 range, rated 20 A at 30 °C with a B curve (magnetic trip between 3 and 5 times In). The B curve means it trips fast on moderate overloads — typical for resistive or general-purpose loads where you want protection without nuisance tripping from small inrush. The 10 kA Icu at 440 V AC (30 kA at 230 V AC) tells you it can interrupt a fault up to that level without welding its contacts, which is the figure you need for SCCR coordination downstream of a transformer or main panel.

Occupies 6 modules of 9 mm pitch (54 mm width total) on the DIN rail. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible conductors; strip length is 14 mm and tightening torque is 2 N.m. The toggle handle gives local ON/OFF indication, and a contact position indicator confirms isolation status — useful when verifying the circuit is dead before working downstream. Tropicalisation per IEC 60068-1 means it handles 95 % relative humidity at 55 °C without condensation issues, so it's fine for non-conditioned enclosures in humid environments.

Selectivity and coordination

The Ics (service breaking capacity) is 15 kA at 440 V AC, which is 100 % of the Icu at that voltage — meaning after clearing a fault at that level, the breaker is still usable, not destroyed. That's a practical advantage for maintenance spares planning: fewer replacements after fault events.