Skip to main content
Schneider Electric C63F31M500

C63F31M500 ComPacT NSX 630F Circuit Breaker, 500 A, 36 kA at

MPN C63F31M500
Obsolete

Schneider Electric ComPacT NSX series, NSX630F, 3P circuit breaker, 500 A rated, MicroLogic 1.3 M electronic trip unit, 36 kA Icu at 415 V AC, motor protection application.

$979.08 – $2,937.06 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C63F31M500 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C63F31M500 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The C63F31M500 is a Schneider Electric ComPacT NSX630F three-pole molded-case circuit breaker with a MicroLogic 1.3 M electronic trip unit, rated 500 A at 65 °C.

At 480 V AC under UL 60947-4-1 it holds 35 kA Icu, so it crosses the Atlantic without derating much. The MicroLogic 1.3 M adds short-time (S) and instantaneous (I) protection — the S band lets you coordinate with downstream starters for selective tripping on a bolted fault.

The 140 mm width, 255 mm height, and 110 mm depth fit standard MCC bucket cutouts. Front connections top and bottom with a 45 mm connection pitch — matches the usual bus-bar tap spacing on a 400 A to 630 A MCC section.

Electrical durability and power dissipation

Mechanical endurance is 15,000 cycles. Electrical durability at rated current (In) at 440 V is 4,000 cycles; at half-rated current (In/2) it doubles to 8,000 cycles. That's typical for a 500 A frame — enough for a motor starter duty cycle of a few operations per hour over a decade. Power dissipation per pole is 25 W, so at 500 A three-pole load the breaker dumps about 75 W into the enclosure — factor that into the panel's thermal budget if it's densely packed.

MPN