Specifications

C63H31M500 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C63H31M500 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The C63H31M500 is a Schneider Electric ComPacT NSX630H molded-case circuit breaker (MCCB) with a 500 A electronic MicroLogic 1.3 M trip unit, designed specifically for motor protection in three-phase AC networks. It's a 3-pole unit rated for 500 A at 65 °C, meaning it's sized for a motor load drawing that full current continuously in a warm panel — no derating guesswork at standard ambient. The MicroLogic 1.3 M trip unit is electronic, not thermal-magnetic. That matters for motor starting — it gives you adjustable short-time and instantaneous protection (S and I curves per the spec), so you can set the trip point above the inrush without losing coordination downstream. Category A utilization means it's not intended for current-limiting duty; it's a standard-break device for distribution and motor circuits.

Front connections top and bottom, with a 45 mm connection pitch, so busbar or cable lugs land cleanly on the line and load side. IP40 front face keeps accidental tool contact out; IK07 impact rating means it survives a knock during panel assembly.

The interrupting rating varies with system voltage, which is typical for an MCCB. At 240 V AC it's 100 kA Icu; at 415 V AC it's 70 kA; at 440 V AC it's 65 kA; at 500 V AC it's 50 kA; at 525 V AC it's 35 kA; and at 690 V AC it's 20 kA — all per IEC 60947-2. For UL 60947-4-1 applications, it's rated 85 kA at 240 V AC, 65 kA at 480 V AC, and 20 kA at 600 V AC. That's a wide voltage range, so it fits 400 V class and 480 V class systems without needing a different frame.

Durability and environmental limits

Mechanical durability is 15,000 cycles; electrical durability depends on the load — 8,000 cycles at 440 V at half-rated current, 4,000 cycles at full rated current, and 2,000 cycles at 690 V at full current. That's solid for a motor-protection breaker in a machine that cycles a few times per shift.

MPN