Skip to main content
Schneider Electric CAD50P7TQ

Schneider CAD50P7TQ TeSys Deca Auxiliary Contactor, 5NO, 230

MPN CAD50P7TQ
Active

Schneider Electric TeSys Deca auxiliary contactor, 5 normally-open poles, 230 V AC 50/60 Hz coil, bulk quantity of 10.

$55.40 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

CAD50P7TQ specifications
ParameterValue
Coil typeStandard
Control circuit typeAC
Main product or component typeAuxiliary contactor
Coil voltage230 V AC 50/60 Hz
Utilization categoryAC-15 AC-14
IP ratingIP2X
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-60...80 °C
Depth86 mm
Width45 mm
Height77 mm
ApplicationControl circuit
Contact operationMechanically linked conforming to IEC 60947-5-1
Operating temperature-40...70 °C at Uc -5...60 °C at 0.8...1.1 Uc

Product details

The CAD50P7TQ is a TeSys Deca auxiliary contactor — a control-circuit relay with 5 normally-open poles, intended for switching signal loads in motor starter or automation panels. The 6 kV impulse withstand confirms it can handle typical switching surges without flashover. It's rated for utilisation categories AC-15 and AC-14, so it switches electromagnetic loads (contactors, relays, solenoids) and resistive loads in control circuits. The mechanically linked contacts per IEC 60947-5-1 are a safety feature: if one NO welds shut, the others cannot close, which matters for safety circuits where you need to guarantee a break.

If you need a drop-in replacement for a new design, look at the current TeSys Deca range with the same pole count and coil voltage — but verify the mounting footprint and terminal layout against your panel cut-out, as form factors can shift between generations.

The 5 NO contact configuration is fixed — no convertible poles. If your circuit needs a normally-closed auxiliary, this block won't give you one without an external interposing relay. The control circuit voltage limits are: dropout at 0.3 to 0.6 Uc, and operational pick-up at 0.8 to 1.1 Uc at 50 Hz, or 0.85 to 1.1 Uc at 60 Hz. Ambient temperature range is -40 to 70 °C at rated coil voltage, narrowing to -5 to 60 °C if you run at the lower end of the voltage band (0.8 Uc). Storage range is -60 to 80 °C. The TH protective treatment per IEC 60068 means it's coated against humidity and condensation — fine for unheated enclosures in temperate climates. Vibration resistance: 2 gn at 5-300 Hz with contacts open, 4 gn with contacts closed. Shock: 10 gn open, 15 gn closed. That's typical for general industrial use but not for high-vibration environments like near a large press or crusher — if your panel is on a machine frame that sees repeated shock, you may need a dedicated vibration-rated block.

The CAD50P7TQ carries approvals to IEC 60947-5-1, EN 60947-5, VDE 0660, BS 4794, NF C 63-140, and IEC 60335-1. The UL and CSA certifications are noted on the insulation voltage rating, so it is accepted in North American panels as well as European. IP2X finger protection per VDE 0106 means the terminals are touch-safe when wired — no extra shrouding needed for basic protection.

MPN
CAD50P7TQ