Schneider Electric DOMF01363

DOMF01363 Domae MCB, 3P, 63 A, C Curve, 6000 A

MPN DOMF01363
Active

Schneider Electric Domae miniature circuit breaker, 3P, 63 A, C curve, 6000 A breaking capacity, IEC 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

DOMF01363 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Breaking capacityIcn 6000 A
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
ColorWhite

All specifications

DOMF01363 additional specifications
ParameterValue
Depth71.5 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationProtection
Operating temperature-5...60 °C

Product details

The DOMF01363 is a 3-pole miniature circuit breaker from the Schneider Electric Domae range, rated 63 A with a C curve and an Icn breaking capacity of 6000 A per IEC 60898-1. It clips onto a DIN rail and occupies 6 modules of 9 mm pitch (54 mm total width). The thermal-magnetic trip unit provides overload and short-circuit protection for AC circuits up to 400 V at 50/60 Hz.

The C curve means the magnetic trip operates at 5 to 10 times the rated current (315 to 630 A), which suits loads with moderate inrush — think lighting banks, small transformers, or motor circuits where the start-up surge is higher than a B curve would tolerate but not as high as a D curve demands. The 6000 A Icn (rated short-circuit breaking capacity) is the maximum fault current the breaker can safely interrupt at 400 V AC; for installations with higher prospective fault current, a breaker with a higher Icn (e.g. 10 kA or 25 kA) would be needed.

Tunnel terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible conductors; tighten to 3.5 N.m. Strip 14 mm of insulation. The IP20 rating on the body (IP40 in a modular enclosure) means it is protected against solid objects larger than 12 mm (fingers) but not against moisture — install inside a panel. Comb busbar compatible for multi-pole distribution.