Skip to main content
Schneider Electric ENW13211

Schneider Electric ENW13211 EasyPact NW Circuit Breaker, 100

MPN ENW13211
Active

Schneider Electric EasyPact NW, circuit breaker, ENW13211, 3P, 1000 A at 40 °C, 66 kA Icu at 440 V AC, fixed mount, rear connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13211 key specifications
ParameterValue
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C

All specifications

ENW13211 additional specifications
ParameterValue
Pollution degreeclass 3
Depth196 mm
Width276 mm
Height301 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric ENW13211 is a 3-pole EasyPact NW circuit breaker rated 1000 A at 40 °C, built for distribution duty in AC networks at 50/60 Hz. For selective coordination with downstream gear, the short-time withstand (Icw) is 50 kA for 1 second, and the making capacity (Icm) is 75 kA — both at 220...440 V AC. That's a Category B breaker (utilisation category B), so it's designed for selectivity in distribution, not just cable protection.

Fixed mount on a rail base plate — no draw-out cradle here. Connection is rear, horizontal or vertical, with a 70 mm pitch without spreader. The footprint is 276 mm wide by 301 mm tall by 196 mm deep.

Durability and environmental range

Mechanical endurance: 20,000 cycles with maintenance, 10,000 without. Electrical endurance: 5,000 cycles at 440 V AC without maintenance. Max breaking time is 35 ms, max closing time 70 ms. The contact position indicator is fitted — a green/red flag visible on the front so you can confirm open/closed without metering.

MPN
ENW13211