Schneider Electric EasyPact NW, ENW13217, 4P drawout circuit breaker, 630 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13217 key specifications
ParameterValue
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C

All specifications

ENW13217 additional specifications
ParameterValue
Pollution degreeclass 3
Depth277 mm
Width358 mm
Height322 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The ENW13217 is a 4-pole drawout circuit breaker from the Schneider Electric EasyPact NW range, rated 630 A at 40 °C and built to IEC 60947-2 for distribution duty. The 66 kA Icu at 220...440 V AC 50/60 Hz is the ultimate breaking capacity — the maximum fault current it can safely interrupt once. The 55 kA Ics service breaking capacity is the figure that matters for repeated fault clearing: it can break and then be reclosed without inspection, which is the real-world requirement for a main breaker in an industrial distribution panel. The 50 kA Icw for 1 second tells you it withstands short-time fault current for coordination with downstream devices — essential for selective tripping in a multi-level system. Rated insulation voltage is 1000 V AC, and impulse withstand is 12 kV — this breaker is designed for 440 V AC operational voltage but with headroom for systems where transient overvoltages are common. The IP30 enclosure protection is typical for a drawout breaker mounted inside a switchgear cubicle — not for outdoor or washdown locations.

Drawout mounting on a rail base plate — the breaker chassis slides into a fixed cradle, allowing safe isolation without unbolting power cables. Connection pitch is 70 mm without spreader, rear-connected, with horizontal and vertical orientation options. Neutral position is left. Dimensions: 358 mm wide, 322 mm high, 277 mm deep. The 4P 3d protected poles configuration means three poles have thermal-magnetic protection and the fourth (neutral) is switched but not protected — verify your system's neutral earthing arrangement before specifying.

MPN