Schneider Electric ENW21428 EasyPact NW Control Unit, LSIG,

MPN ENW21428
Active

Schneider Electric EasyPact NW, control unit, Trip System 6.0A, LSIG, 800-4000 A, 690 V AC, 50/60 Hz, 4P/3P, fixed mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW21428 specifications
ParameterValue
Display typeDigital display
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth75 mm
Width55 mm
Height200 mm
Operating temperature-5...70 °C

Product details

The Schneider Electric ENW21428 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. It carries a Trip System 6.0A with LSIG protection — long-time, short-time, instantaneous, and ground-fault — covering the full 800 to 4000 A trip rating range at 690 V AC, 50/60 Hz, per IEC 60947-2.

What the LSIG protection curve means for your feeder

LSIG gives you four independently adjustable protection elements: long-time pickup (Ir) from 0.4 to 1 x In with nine settings and delay adjustable 0.5 to 24 s at 6 x Ir; short-time pickup (Isd) from 1.5 to 10 x Ir with nine settings and delay 100 to 400 ms; instantaneous pickup (Ii) from 2 to 15 x In, also nine settings, with an Off position for coordination schemes; and ground-fault pickup (Ig) adjustable from 0.2 to 1 x In for frames up to 1000 A, or 500 to 1200 A for larger frames, with five delay settings.

Integration into the EasyPact NW frame

This control unit mounts fixed into the EasyPact NW breaker chassis — no DIN rail, no panel cutout. The 75 mm depth, 55 mm width, and 200 mm height fit the standard NW drawout cradle. Neutral position is left-side; the unit supports 3-pole (3D), 4-pole (4D), and 3D + N/2 configurations, with neutral protection selectable as unprotected, 0.5 x Ir, or 1 x Ir. Zone selective interlocking (ZSI) is built in, so you can daisy-chain multiple breakers for faster fault isolation on a bus tie scheme.

Thermal memory and fault diagnostics

The Trip System 6.0A retains a thermal model of the conductor temperature for 20 minutes before and after a trip event. That prevents immediate reclose onto a still-hot cable — useful on motor feeders where repeated starts can overheat the branch circuit. The digital display shows the cause of the last trip: internal fault, short-circuit, overload, or earth fault, which cuts troubleshooting time on a downed line.