Skip to main content
Schneider Electric ENW24103

Schneider Electric ENW24103 EasyPact NW Circuit Breaker, 125

MPN ENW24103
Active

Schneider Electric EasyPact NW drawout circuit breaker, 3P, 1250 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24103 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24103 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

It's built to IEC 60947-2 for distribution duty — the standard that covers air circuit breakers for industrial power systems. The drawout mounting means the breaker slides out of its cradle for safe maintenance without disturbing the busbars, a real time-saver when you're swapping a unit on a live panel. Breaking capacity is 50 kA Icu at 220...440 V AC and 42 kA at 690 V AC, with matching Ics (service breaking capacity) at the same levels — meaning it can clear a fault and be reclosed without repair. Rated insulation voltage is 1000 V AC, so it's comfortable on 690 V systems with headroom. Impulse withstand is 12 kV, which covers most industrial surge environments.

If your panel runs hotter than 40 °C, you'll need to derate per the manufacturer's curve. Electrical durability is 6,000 cycles at 440 V and 4,000 at 690 V without maintenance, which aligns with Category B utilization per IEC 60947-2. The 25 ms maximum breaking time is fast enough to coordinate with downstream breakers in a selective scheme.

MPN
ENW24103