Skip to main content
Schneider Electric ENW24127

Schneider Electric ENW24127 EasyPact NW Circuit Breaker, 125

MPN ENW24127
Active

Schneider Electric EasyPact NW air circuit breaker, ENW24127, 4-pole, 1250 A at 40 °C, 50 kA Icu at 440 V AC, fixed-mount, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24127 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24127 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

If your panel runs hotter (up to 60 °C per the operating range), you'll need to derate — the 40 °C figure is the benchmark for sizing the main breaker on a switchboard or distribution bus. For repeated fault interruption (the service breaking capacity, Ics), the same 50 kA applies at 440 V and 42 kA at 690 V. That's Category B utilization, meaning it's rated for selectivity in distribution — it will clear a downstream fault without taking upstream feeders off-line.

Deployment context — where this breaker goes

This is a fixed-mount, rear-connected air circuit breaker for distribution switchboards. The 537 mm width, 352 mm height, and 297 mm depth — plus the 115 mm connection pitch without spreader — are the dimensions you need to verify against your bus-bar layout and cabinet cutout. Pollution degree 4 per IEC 60664-1 means it's rated for harsh environments with conductive dust or heavy condensation — typical in heavy industry, cement plants, or outdoor substations inside a shelter. The neutral position is left, with protection configurable as 3D (no neutral protection), 3D + N/2 (half-rated neutral), or 4D (full neutral protection).

MPN