Skip to main content
Schneider Electric ENW24237

Schneider Electric ENW24237 EasyPact NW Circuit Breaker, 800

MPN ENW24237
Active

Schneider Electric EasyPact NW, ENW24237, fixed-mount air circuit breaker, 800 A, 4P, 50 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24237 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24237 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24237 is a fixed-mount EasyPact NW air circuit breaker rated for 800 A at 40 °C, configured as a 4-pole unit (4P). It's designed for distribution duty in industrial switchboards and main low-voltage panels, built to IEC 60947-2. Breaking capacity is 50 kA Icu at 220...440 V AC, 42 kA Icu at 690 V AC — both at 50/60 Hz. The Ics (service breaking capacity) matches the Icu at those voltages, meaning the breaker can be reclosed after clearing a fault at full rated interruption without derating. That's Category B utilization, with 6000 cycles electrical durability at 440 V without maintenance. Rated insulation voltage is 1000 V AC, operational voltage 690 V AC, with a 12 kV impulse withstand.

For a BOM line requiring a 800 A, 4P, fixed-mount air breaker with 50 kA interrupting capacity at 440 V, this order code fits directly.

IP40 protection — suitable for indoor panel mounting where no water spray is present. Push-button control on the front; contact position indicator visible. Ambient operating range is -5 to 60 °C.

Conforms to IEC 60947-2. The breaker carries a 12 kV rated impulse withstand voltage (Uimp). Storage temperature range: -40 to 85 °C without control unit, -25 to 85 °C with control unit.

MPN
ENW24237