Schneider Electric EasyPact NW, fixed-mount circuit breaker, 2000 A at 40 °C, 4P, 50 kA Icu at 440 V AC, IEC 60947-2, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24241 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24241 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The 50 kA Icu at 220...440 V AC (conforming to IEC 60947-2) is the maximum fault current it can safely interrupt once; the same 50 kA Ics rating means it can clear that fault and be reclosed without maintenance, which matters for service-entrance or feeder duty where a fault is rare but must not force a breaker swap. At 690 V the Icu drops to 42 kA — still substantial for 690 V distribution. The 4-pole (4P) design with neutral on the right handles three-phase plus neutral distribution. Rear vertical/horizontal connection pitch is 115 mm without spreader, so panel buswork or cable lugs need to match that spacing. IP40 enclosure protection means it is suitable for indoor switchboards — not washdown or outdoor exposure. Pollution degree 4 per IEC 60664-1 is the most severe industrial pollution class (conductive dust or wet conditions inside the enclosure), so this breaker is built for harsh environments inside a panel.