Schneider Electric EVS16H3MW20 EasyPact EVS Circuit Breaker,

MPN EVS16H3MW20
Active

Schneider Electric EasyPact EVS, EVS16H3MW20, 3-pole drawout circuit breaker, 1600 A rated current, 65 kA breaking capacity at 440 V AC, EVS Trip System2.0.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS16H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS16H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS16H3MW20 is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 1600 A at 40 °C with a breaking capacity of 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC per IEC 60947-2. The drawout mounting lets you rack the breaker out for maintenance or replacement without disturbing the bus connections, a standard requirement for main and tie breakers in industrial switchboards. The EVS Trip System2.0 electronic trip unit provides LI protection — overload (long-time) and instantaneous short-circuit. The 20-minute thermal memory means the trip curve remembers prior heating, preventing nuisance reclosure on a hot breaker after a fault.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability: 5,000 cycles at 440/690 V AC without maintenance per IEC 60947-2. Suitability for isolation is confirmed to IEC 60947-2, meaning the open contacts provide a visible air gap that meets safety isolation requirements — important for lockout/tagout procedures.