Skip to main content
Schneider Electric EVS20H4MW6A

Schneider Electric EVS20H4MW6A EasyPact EVS Circuit Breaker,

MPN EVS20H4MW6A
Active

Schneider Electric EasyPact EVS, EVS20H4MW6A, drawout circuit breaker, 4P, 2000 A, 65 kA Icu at 440 V AC, electronic trip unit, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS20H4MW6A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS20H4MW6A additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS20H4MW6A is a 4-pole drawout circuit breaker from the EasyPact EVS range, rated 2000 A continuous at 40 °C with an electronic trip unit (EVS Trip System6A). IEC 60947-2 Category B utilisation confirms it is designed for selectivity (discrimination) with downstream breakers, so a fault on a branch clears without tripping this main breaker.

Drawout mounting and panel integration

Drawout mounting means the breaker slides in and out of a fixed cradle — no need to disconnect power cables for removal or replacement. This is standard for main breakers where uptime matters: pull the breaker for maintenance or swap without de-energising the bus. Mounting support is a rail or base plate; connection is rear with a 115 mm pitch without spreader. Vertical or horizontal connection orientation gives flexibility in cabinet layout. Dimensions: 556 mm wide × 439 mm high × 395 mm deep — verify the cubicle depth before specifying.

Protection and trip unit

The electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. The 20-minute thermal memory means the trip curve accounts for prior heating — important when re-energising after a fault, preventing nuisance trips on a still-hot cable. Fault indication covers internal fault, overload, short-circuit, and earth fault on the digital display. Maximum breaking time is 25 ms — fast enough to limit let-through energy for downstream equipment.

MPN
EVS20H4MW6A