Skip to main content
Schneider Electric EVS25H3MW20

Schneider Electric EVS25H3MW20 EasyPact Circuit Breaker, 250

MPN EVS25H3MW20
Active

Schneider Electric EasyPact EVS, EVS25H3MW20, 3-pole drawout circuit breaker, 2500 A rated current, 65 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS25H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS25H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

It carries a 2500 A rated current at 40 °C and a 65 kA Icu breaking capacity at 220…440 V AC, per IEC 60947-2.

The EVS Trip System2.0 is an electronic trip unit rated at 2500 A, with LI protection — overload (long-time) and instantaneous short-circuit. That matters on a motor feeder or a welder circuit where repeated starts can cook the cable if the breaker doesn't account for prior heating.

This is a drawout breaker — it mounts on a rail base plate, with rear vertical or horizontal connections. The 115 mm connection pitch (without spreader) and the 441 mm width, 439 mm height, 395 mm depth give you the envelope for panel layout. IP40 protection means it's fine inside a clean indoor switchboard but not for washdown environments. Pollution degree 4 per IEC 60664-1 tells you it's rated for harsh conductive environments — think industrial atmospheres with dust or condensation.

Electrical durability is 5,000 cycles at 440/690 V AC without maintenance. That electrical figure is Category B per IEC 60947-2, meaning the breaker is designed for selective coordination — it can hold in during a downstream fault to let a branch breaker clear first.

Rated insulation voltage (Ui) is 1000 V AC. Breaking capacity is 65 kA Icu at 220…440 V AC, and 50 kA Icu at 690 V AC. Maximum breaking time is 25 ms, maximum closing response time is 70 ms. The 3-pole, 3-protected-poles (3d) configuration means all three poles have the same protection — no solid-neutral variant here.

MPN