Skip to main content
Schneider Electric EZ9F26140

Schneider Electric EZ9F26140 Easy9 MCB, 40 A, 1P, B-Curve, 6

MPN EZ9F26140
Obsolete

Schneider Electric Easy9 series, EZ9F26140 miniature circuit breaker, 1P, 40 A, B-curve, 6 kA breaking capacity at 230 V AC, DIN rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9F26140 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1
Poles1P
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

EZ9F26140 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree2
ColorGrey (RAL 7035)
Depth66.5 mm
Width18 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The 6 kA breaking capacity (Icn) at 230 V AC per IEC 60898-1 tells you it can safely interrupt a fault current up to 6,000 A without welding its contacts or cascading damage upstream. Thermal-magnetic trip technology gives you two protection layers: the thermal bimetal handles sustained overloads (e.g., a 45 A draw on a 40 A circuit), while the magnetic solenoid reacts instantly to short-circuit currents. The 40 A rating and 1-pole format suit single-phase branch circuits feeding a 9.2 kW resistive load at 230 V.

Approvals include IEC 60898-1 compliance, which covers the standard for MCBs used in household and similar installations. The part carries a suitability-for-isolation marking per that standard, meaning you can safely use it as a disconnect under load — the contact position indicator confirms open/closed state visually. Pollution degree 2 rating suits normal indoor environments;

The tunnel-type terminals accept 1–25 mm² flexible or 1–35 mm² rigid copper, with a tightening torque of 3.5 N·m. That covers most branch-circuit conductors up to a 40 A load. Depth is 66.5 mm, height 81 mm, width 18 mm — fits in a standard 2-module slot. The grey (RAL 7035) housing matches the Easy9 family aesthetic for a clean panel layout.

MPN
EZ9F26140