Schneider Electric EZ9R03263

Schneider Electric EZ9R03263 Easy9 RCCB, 63A 30mA Type AC, 2

MPN EZ9R03263
Active

Schneider Electric Easy9 RCCB, residual current circuit breaker, 2P, 63 A, 30 mA, Type AC, 230 V AC, clip-on DIN rail.

$23.84 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9R03263 key specifications
ParameterValue
Control typeToggle
Voltage230 V AC 50 Hz
Insulation voltage ui440 V AC
Poles2P
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to IEC 61008-1

All specifications

EZ9R03263 additional specifications
ParameterValue
ColorGrey (RAL 7035)
Depth72 mm
Width36 mm
Height82 mm
Electrical life cyclesAC: 2000 cycles 230 V AC 50 Hz
Mechanical life cycles5000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric EZ9R03263 is an Easy9 range residual current circuit breaker (RCCB) — a 2-pole, Type AC device rated for 63 A continuous load with 30 mA earth leakage sensitivity.

The 63 A rated current (In) and 30 mA leakage sensitivity are the two numbers that decide whether this RCCB fits your distribution board. Type AC means it detects sinusoidal AC earth faults only; if your load includes pulsed DC (e.g., VFDs, UPS, EV chargers), you need a Type A or B device instead. Mechanical durability is 5000 cycles; electrical durability is 2000 cycles at rated load. That is typical for a residual current device — it is not a switching device for frequent operation, but a protective device meant to trip only on fault. The instantaneous trip (no intentional time delay) means it clears earth faults without waiting, which is the right behaviour for personal protection.

Where it goes in the panel

This RCCB is an outgoer device — it sits downstream of the main switch or incoming breaker, protecting a subcircuit or a group of MCBs. The neutral is on the left, and the connection pitch between phases is 18 mm. Terminal tunnels accept 1…35 mm² rigid or 1…25 mm² flexible cable; tighten to 3.5 N·m. Strip 16 mm of insulation. The IP20 finger-safe terminals are fine inside a closed panel but not for wet or dusty locations.