Schneider Electric EZC100F3045

Schneider Electric EZC100F3045 EasyPact EZC100F Circuit Brea

MPN EZC100F3045
Obsolete

Schneider Electric EasyPact EZC100F, 3-pole circuit breaker, 45 A thermal-magnetic TM-D trip unit, 25 kA Icu at 240 V AC, front connection, toggle control.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100F3045 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100F3045 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC100F3045 is a 3-pole EasyPact EZC100F moulded-case circuit breaker from Schneider Electric, rated 45 A at 40 °C (45 A at 50 °C with the TM-D thermal-magnetic trip unit). The 25 kA Icu at 220…240 V AC is the interrupting capacity that determines whether this breaker clears a fault without upstream devices needing to trip — at 380…415 V AC that figure drops to 10 kA Icu, and at 440 V AC to 7.5 kA Icu, so selectivity coordination needs to be checked at your actual system voltage. The 690 V AC rated insulation voltage (Ui) and 550 V AC maximum operational voltage (Ue) cover standard 400 V distribution panels with headroom. IP20 finger protection on the front face is fine for enclosed panels; the IK07 impact rating means the enclosure can take a light tool strike during installation without cracking the housing.

Certified to EN/IEC 60947-2 and EN/IEC 60947-1, plus JIS C8201-2-2 and GB/T 14048.2 for Japanese and Chinese markets. Pollution degree 3 (conductive pollution from condensation or light dust) is standard for industrial control panels. No earth-leakage or neutral protection built in; this is a straight overload and short-circuit device for 3-phase loads.

MPN
EZC100F3045